This Power AC / DC Converter was designed for open air field applications, to be supportive for battery charge for mobiles from line voltage with high power.
The provided stands allows a stable distance to the earth and the required ventilation of the converter.
Input is electrically isolated from output according to EN 60950-1.
Input voltage: | 230 V AC ±15 %, 50 Hz. |
Consumption: | max. 16 A sinusoidal conform to EN 61000-3-2 |
Output voltage: | 28 V DC +3, -5 % for 85 A, 24 V DC +3, -5 % for 100 A |
Output current: | max. 100 A 20 °C, limited for overload or increased temperature |
Output release: | only after proved connection with vehicles supply system |
Output protection: | no-load proof short-circuit proof |
Inrush current: | < 30 A pk at 230 V AC |
Efficiency: | typ. 83 % at 230 V AC and 20 to 80 % load |
Technical specifications
refer to data sheet: 00888
Isolation voltage: | floating output in accordance to VDE 0554 |
MTBF: | >15.000 h at 25 °C |
Dimensions: | 300 x 480 x 191 mm, (W x D x H) with stands |
Weight: | ≤15 kg |
Housing: | • made of cast G-AlSi12 (DIN 1725) • two carrying handles integrated in the heat sink • captive connector covers • ground terminal M8 on rear • four pierced holes a’ Φ 25 mm for a steel cable as anti-theft device |
Protection: | IP 66 (EN 60529) |
Operating temp.: | -46 °C to +63 °C |
Humidity: | 95 % rel. with thawing |
Salt fog: | 5 % at 35 °C |
Vibration.: | Fig. 514.5C3 for wheeled vehicles |
Shock: | 10 x 10 g / 6 ms |
EMI / EMC: | MIL-STD-461C respectiv. D |
ESD.: | EN 61000-4-2 |
Lightning protect.: | STANAG 4145 / AEP4, annex a (Land) /07.1990 |
NEMP: | STANAG 4236, Issue 2 |
1) 3 m screened lead, 230 V AC with integrated 16 A PRCD-S guard circuit (TBD) and CEE – 230 V respectively Souriau Series 847 connectors.
2) 5 m screened lead (power supply to mobile) with VG 95234 connectors of type M-24-12PN, respectively
24-125 N